RUPALIT® Safety

RUPALIT® Safety Litz wires will revolutionize the design of your transformer in accordance with IEC 60950, Annex C and Annex U; VDE 0805; UL60950 (applied for)

Maximize safety
minimize costs.
View technical data sheet.

Technical and economic benefits:

  • 50% reduction in the size
    of transformers
  • 65% reduction in the
    weight of transformers
  • Insulation between
    primary and secondary
    winding no longer
    necessary
  • Inter-layer insulation no
    longer necessary
  • Creepage and leakage
    distances are included
    in the wire
  • Encapsulation not necessary
  • Much faster winding time


Examples of application:

  • High Frequency transformers
  • High Frequency transmission devices
  • High Frequency chokes
  • Electronic ballasts

Construction:

  • Enamel insulated copper
    wires (magnet wire)
    (0.02-1.6 mm dia.,
    AWG 13-52)
  • Conductor cross-section
    in compliance with DIN
    or customer requirements

Isolation material:

  • *Polyester foil, 150 °C
    (Mylar©)
  • P.E.N. foil (XR 20), 155 °C
  • **Polyimide foil, 220 °C
    (Kapton©, Kapton©CR)

 reg.-no.: 122034
Multi layer sealed Mylar©

Working voltage:
max. 400 Vrms
max. 1000 Vp
Frequency: max. 500 kHz

Material Group: B
(max. 165 °C)

Break down voltage:
4.8 kV

 reg.-no.: 6720
Multi layer sealed
Kapton© CR

Working voltage:
max. 400 Vrms
max. 1000 Vp
Frequency: max. 500 kHz

Material Group: F

Break down voltage:
~ 7-8 kV
View technical data sheet.

Optimized Winding = Optimum in Power Efficiency

In the scope of the German Federal Government´s 5th Energy Research Program "Innovation and New Energy Technologies" the Rudolf Pack GmbH&Co. KG join forces a research project together with
more...

Our agencies worldwide

Get in contact to be informed about our products and their scope of applications!
Proceed to our list of international distributors and find your personal distributor for your country...
more...